SeaLand 3100 Spezifikationen Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 51
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
APT3100 Smart Pressure Transmitter Operation Manual M3100-EO1G
10
Duon System Co.,Ltd.
2.10 Installation of Explosion Protected Type Transmitters
2.10.1 KOSHA Certification
Caution for KOSHA Flameproof is following type.
[Note1] Model APT3100 diaphragm sealed for potentially explosive atmosphere:
z Type of Protection and Marking Code: Ex d C T6
z Temperature Class: T6
z Ambient Temperature: -20 ~ 60'C
z Process Temperature: Max. 80'C
[Note2] Electrical Data
z Supply Voltage: Maximum 45 Vdc
z Output signal: 4 ~ 20mA, maximum 22mA
[Note3] Installation
z All wiring shall comply with local installation requirement.
z The cable entry devices shall be of a certified flameproof type, suitable for conditions of
use.
[Note4] Operation
z Wait one minute after power -disconnection, before opening the enclosure.
z Take care not to generate mechanical spark when access to the instrument and peripheral
devices in hazardous location.
[Note5] Maintenance and Repair
z The instrument modification or parts replacement by other than authorized representative
of DUON System is prohibited and will void KOSHA Flameproof.
2.10.2 KEMA / ATEX Certification
ATEX Certification number : KEMA07ATEX0103
CE 0344
II 2 G
Note 1. Model APT3100 for potentially explosive atmosphere
z Ex d IIC T6...T4
z Operating Temperature : -20 T
amb
+60°C
z T6 for process 85°C;
z T5 for process 100°C;
z T4 for process 130°C;
Seitenansicht 13