STEP 1: Carefully unpack toilet and place it in the position intended. Center the toilet in the
selected position and assure that adequate clearance is available for opening the seat and lid.
Check the front and sides of the toilet to insure that it will set at against the oor. Determine the
best location for the ush switch panel. It is recommended that it be near the toilet but not hidden
by the toilet lid in the “up” position. Avoid a location susceptible to direct water spray.
STEP 2: Mark the oor at the rear corners and the front center of the ceramic bowl. Remove the
ceramic bowl and set aside (gs. 1, 2).
STEP 3: Measure the distance between the rear corner marks on the oor and divide by 2 to nd
the centerline. Using a carpenter’s square, draw a centerline on the oor that intersects the mark
for the front center of the bowl (g. 3).
STEP 4: Choose an inlet conguration for the electrical wiring and water line hole location: (a)
through the rear wall, or (b) through the oor.
STEP 5: For electrical cables/wiring and water line installations through the rear wall, measure
up a minimum of 1 inch (25 mm) and 2 inches (51mm) to the right of the centerline (g. 4) for the
electrical cables, and 2 inches (51 mm) to the right of the centerline for the water line. Mark the
hole locations.
Toilet Requirements:
water supply hose).
VACUFLUSH
®
4809 TOILET INSTALLATION GUIDE
Fig. 1
Fig. 2
Fig. 3
These locations are for the water and electrical
supply line holes in through-the-wall installations.
WALL
FLOOR
toilet
centerline
water line
location
1 in.
(25 mm)
2 in.
(51 mm)
Fig. 4
the template ush with the mark for the front edge of the toilet bowl (g. 5). Tape the template to
the oor.
and electrical wiring holes (if routing these through the oor). Remove the template from the oor.
Fig. 5
Fig. 6
Below-Floor Installation
Above-Floor Installation
IMPORTANT: The preferred oor ange installation method is to mount the ange directly on the
nished oor. However, if the bottom of oor ange and bottom of ceramic toilet must be mounted
toilet (see illustrations below) or leakage will result.
handling.
discharge plumbing. Mark the oor through the eight countersunk mounting holes. Remove the
Fig. 7
STEP 11: Route the vacuum hose from the vacuum generator or vacuum tank up through the
STEP 13: Insert the discharge ange and connected hose or pipe into the discharge hole and
STEP 15: Install oor ange adapter with words “THIS SIDE UP” facing up. Tighten adapter to
Note:
basic Dometic ush switch are on the next page.
included with each ush switch assembly.
(The cable supplied with the basic Dometic ush switch will have a Deutsch connector.)
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 17
Fig. 16
the oor or through the wall to connect to toilet. (See wiring diagrams on next page. If Deutsch
connectors (shown) are not being used, refer to wiring diagram to make proper connections in
washer head screws and support plates
provided. Be sure to mount the brackets as
shown on the template (g. 14).
adapter. Connect the exible water hose to the
line. Connect the cable/wiring from ush switch
wiring. Connect the cable/wiring from vacuum
generator and power source to the toilet’s
spray or grease. Pick up the toilet and insert plastic base assembly into discharge adapter. Make
sure mounting brackets on oor do not interfere with bottom of ceramic toilet (g. 15). If the
mounting brackets interfere, loosen mounting screws and adjust bracket location accordingly.
STEP 22: Insert the two plastic ange bushings
into the toilet mounting holes and secure the
toilet to the mounting brackets with the two at
to drive fasteners into mounting brackets at a
downward angle.
STEP 23: Press the decorative screw covers
2 in.
(51 mm)
electric cable
location
Kommentare zu diesen Handbüchern